Dormakaba Panic Exit Device PHA 1 & 2 Point Fire Rated Double Door Set 1000x2270mm - PHA216C - Silver
The Dormakaba PHA216C is a modular panic exit device set designed for double fire and smoke check doors. It provides single point locking on the active leaf and two point locking on the inactive leaf, using steel latch components and a security anti-thrust latch for reliable emergency egress.
Important: Doors higher than 2500 mm lie outside the scope of EN 1125.
Key Features
- Modular panic exit device for double door applications.
- One point locking on active leaf and two point locking on inactive leaf.
- Fire rated configuration for fire and smoke check doors.
- Security anti-thrust steel latch.
- Steel latch keeper assemblies.
- Compatible with PHT external fittings for various door types.
- Suitable for narrow stile and full face timber doors.
Fire Rated
- Approved for use on fire and smoke check door assemblies.
Specifications
- Item Code: PHA216C
- Brand: Dormakaba
- Device Type: Panic exit device
- Configuration: Double door set
- Locking Points: 1 point active leaf, 2 point inactive leaf
- Maximum Door Leaf Width: 1000 mm
- Maximum Door Leaf Height: 2270 mm
- Maximum Door Leaf Weight: 200 kg
- Latch Type: Security anti-thrust steel latch
- Finish: Silver
What's In The Box
- PHA2102F module
- PHA2201 module
- 2 × PHA2104 modules
- PHX03 component
- PHX04 component
- Fixing components
Suitable Uses
- Double fire and smoke check doors in commercial buildings.
- Emergency exits requiring panic hardware.
- Doors up to 1000 mm wide and 2270 mm high.
Dimensions
| Dimension | Size |
|---|---|
| Maximum Door Width | 1000 mm |
| Maximum Door Height | 2270 mm |
| Maximum Door Weight | 200 kg |
PHA2000 Series Item Code Family
| Item Code | Configuration | Description |
|---|---|---|
| PHA201C | 1 Point | Single door modular panic device, fire rated. |
| PHA209C | 3 Point Double Door | Three point modular double door panic device. |
| PHA216C | 1 & 2 Point Double Door | This product |
Frequently Asked Questions
- Is this device suitable for fire doors?
Yes. It is approved for use on fire and smoke check door assemblies. - What door size does this set suit?
It suits door leaves up to 1000 mm wide and 2270 mm high, with a maximum weight of 200 kg. - Can this be used on doors taller than 2500 mm?
No. Doors higher than 2500 mm lie outside the scope of EN 1125.
Additional Information
- Designed for modular configuration within the Dormakaba PHA2000 series.
- Commonly specified on commercial double fire exit doors.
- Ensure correct door size, weight and configuration before ordering to maintain compliance.
dormakaba Warranty
dormakaba Australia Pty Ltd (ABN 14 067 969 466) provides the following warranty on all dormakaba branded products sold in Australia. This warranty is in addition to, and does not limit, your rights under the Australian Consumer Law.
Warranty Summary
How to Make a Claim
- Report the defect promptly. Contact Terry's Tradies Pty Ltd and its associated websites, trading names, and subsidiaries (including Gold Coast Smart Locks) as your point of sale in the first instance. Claims must be lodged no later than 1 month from the date the defect becomes obvious.
- Prepare your documentation. You will need proof of purchase (invoice or receipt), the date of delivery or installation, your name and address, and any maintenance records relevant to the product.
- Make the product available for inspection. dormakaba requires adequate access to the goods, fittings, and fixtures to assess any warranty claim and carry out repairs. If no fault is found, dormakaba's standard costs for inspection, service, and testing apply.
- Warranty work is conducted during normal business hours � 8:00am to 5:00pm, Monday to Friday.
Note: The expense of making a warranty claim (including transport and access costs) is borne by the purchaser.
Exclusions
This warranty does not cover:
- Damage or defects caused by misuse, abuse, neglect, or failure to follow dormakaba's selection, installation, and maintenance instructions
- Fair wear and tear
- Damage arising from installation not carried out by dormakaba or its authorised agents
- Damage caused to the structures the product is installed in, where installation was not by dormakaba or its authorised agents
- Damage caused by circumstances beyond dormakaba's control
- Defects within acceptable industry variances
- Products used other than for their intended purpose
- Damage from exposure to abnormal conditions, including but not limited to extreme temperature, water, fire, humidity, pressure, or stress
- Products that have been modified, built on, or repaired by a third party
- Products not maintained in accordance with dormakaba's care, cleaning, and maintenance instructions (as amended from time to time on the dormakaba website)
- Routine maintenance items (the purchaser's responsibility)
- Products installed, maintained, or operated other than in accordance with dormakaba's instructions
- Overhaul, replacement, or repair work carried out prior to dormakaba's approval of a warranty claim
Important Notes
In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure, and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have goods repaired or replaced if they fail to be of acceptable quality and the failure does not amount to a major failure. Nothing in this warranty limits or excludes these statutory rights.
dormakaba reserves the right to replace defective parts with components of similar quality, grade, and composition where an identical part is unavailable. Refurbished parts or goods of the same type may be used. For discontinued or unavailable products, dormakaba may substitute an equivalent current product. All products replaced under warranty become the property of dormakaba.