Dormakaba Door Closer Part Limiting Stop to suit TS91 TS92 TS93 Slide Rail G-N Channel

Dormakaba

$93.83
(No reviews yet) Write a Review
SKU:
STK DOTS92LS
UPC:
9329673198182
Availability:
Usually same day dispatch (if ordered before 11am)
Adding to cart… The item has been added
Dormakaba logo

Dormakaba Door Closer Limiting Stop to suit TS91 TS92 TS93 Slide Rail

Key features icon Key Features

  • Cushioned limiting stop that slides into the slide rail channel.
  • Adjustable opening limitation between 80 degrees and 120 degrees.
  • Helps prevent the door leaf impacting adjacent walls during normal opening.
  • Suitable for retrofitting into existing compatible slide rail channels.
  • Designed to suit Dormakaba TS91, TS92 and TS93 slide rail door closers.

Fire rating icon Fire Rated

  • Required for fire rated doors when used with compatible TS91, TS92 or TS93 slide rail closer configurations.

Specifications icon Specifications

  • Item Code: DOTS92LS
  • Product Type: Cushioned limiting stop (limit stay)
  • Compatible Closers: TS91, TS92, TS93
  • Mounting: Slide rail G-N channel
  • Adjustment Range: 80 degrees to 120 degrees
  • Fire Rated: Yes (required for fire rated doors)

Contents icon What's In The Box

  • 1 x Cushioned limiting stop for slide rail channel

Suitable uses icon Suitable Uses

  • Fire door installations using TS91, TS92 or TS93 slide rail closer setups where an opening limitation is required.
  • Doors that open toward walls, glazing or joinery where impact protection is needed.
  • Retrofit upgrades to existing slide rail channels to reduce door over travel.

Dimensions

Dimension Size
Opening limitation range 80 degrees to 120 degrees

PDF icon Download PDF Resources

PDF icon Dormakaba TS91 and TS92 Door Closer Brochure

FAQ icon Frequently Asked Questions

  • Is this an overload protection device?
    No. It limits opening during normal use but it is not designed to replace a proper door stop where impact loads are high.
  • Do I need this on a fire door?
    Yes, it is required for fire rated door configurations when using compatible TS91, TS92 or TS93 slide rail closers.
  • Can it be retrofitted into an existing slide rail?
    Yes, it can be added later by sliding it into the compatible slide channel.

Book icon Additional Information

  • In corridors and small rooms, limiting the opening angle helps reduce damage to plaster, glazing and adjacent hardware.
  • If the door is frequently forced beyond the stop point, a floor or wall mounted door stop is usually still required.
  • Set the limitation angle during commissioning so the door clears handles and latches without striking nearby walls.