Tactical 8 Way Power Distribution Module - 12VDC with 1amp Glass Fuses - Monitored Fire Trip Input - DIN Rail Mounting
Key Features
- 8 individually fused outputs to isolate faults instead of shutting down the full system.
- Monitored fire trip input supports a 22K end of line resistor or voltage trip configuration.
- Each output can be programmed to remove power or remain active during fire trip.
- Common fault Single Pole Double Throw relay output for system monitoring.
- Light Emitting Diode indicators for power status and fuse condition.
- 35 millimetre DIN rail mounting for clean cabinet installation.
Specifications
- Item Code: PDM812VDC
- Working Voltage: 12 Volt Direct Current (12 to 13.5 Volt DC output)
- Output Channels: 8
- Total Output Current: 10 Amp continuous (power supply dependent)
- Fuse Per Channel: M205 1 Amp fast blow glass fuse supplied (maximum 3 Amp per channel)
- Fuse Status Indication: Green Light Emitting Diode per channel
- Power Indicator: Green Light Emitting Diode
- Common Fault Output: Single Pole Double Throw relay
- Fire Trip Relay: 10 Amp relay with status Light Emitting Diode
- Working Temperature: 0 to 50 degrees Celsius
- Mounting: 35 millimetre DIN rail clips
- Warranty: 3 years
What's In The Box
- Tactical PDM812VDC 8 way power distribution module.
Suitable Uses
- Power distribution for access control or CCTV systems.
- Security control panels requiring individually fused outputs.
- Installations needing a monitored fire trip input.
- Cabinet builds requiring DIN rail mounted distribution boards.
Dimensions
Download PDF Resources
| PDM812VDC Specifications | |
| PDM8 Installation Manual | |
| PDM8 Wiring Chart |
Frequently Asked Questions
- Can each output behave differently during a fire trip?
Yes. Each output can be individually set to either remove power or remain active during a fire trip event. - What happens if a fuse fails?
The common fault relay changes state and the fault Light Emitting Diode illuminates, allowing remote monitoring. - Is this suitable for DIN rail mounting?
Yes. The module includes 35 millimetre DIN rail mounting clips for control cabinet installation.
Additional Information
- Individually fused outputs help prevent a single device fault from disabling an entire power supply.
- Commonly specified in Australian security and access control cabinets where fault reporting is required.
- Installers should ensure total system current does not exceed the connected power supply or fire trip relay rating.
-
Technical Drawing