Jack Fuse PP5FRUNI Power Port 5 Way Power Distribution Module with Fire Trip - Self Healing Fuses
The Jack Fuse PP5FRUNI is a five way power distribution module with integrated fire trip functionality and self-healing fuses. It is designed for electronic access control systems requiring reliable power distribution and compliance with fire release requirements.
Key Features
- Five individual self healing fused outputs with LED status indicators.
- Integrated fire trip input and monitoring output.
- Field selectable outputs for fire power or standard power.
- Universal mounting footprint for common access control panels.
- 45 degree connectors for easier termination.
- Unfused auxiliary output for expansion.
- Optional DIN rail mounting kit.
Specifications
- Item Code: PP5FRUNI
- Product Type: Power distribution module
- Outputs: 5 fused outputs
- Fuse Type: Self healing resettable fuses
- Fire Trip: Yes
- LED Indicators: Yes
- Mounting: Universal footprint or optional DIN rail
- Form Factor: Circuit board
What's In The Box
- 1 × PP5FRUNI power distribution module
Suitable Uses
- Access control system power distribution.
- Electric lock and reader power circuits.
- Fire trip door release systems.
- Security controller cabinet installations.
Power Port Series - Item Code Family
| Item Code | Outputs | Fuse Type | Description |
|---|---|---|---|
| PP5FRUNI | 5 | Self healing | 5 way fire trip distribution module - This product |
| PP8FR | 8 | Glass fuses | 8 way fire trip distribution module |
| PP8PTC | 8 | Self healing | Premium 8 way distribution module with auxiliary relay |
| PP10HD | 10 | Self healing | 10 way high density fused module |
| PP10MG | 10 | Glass fuses | 10 way modular glass fuse distribution module |
PDF Resources
Frequently Asked Questions
- What are self healing fuses?
Self healing fuses automatically reset after a fault is cleared, removing the need to replace blown fuses. - Can this module connect directly to fire alarm systems?
Yes. It includes fire trip input and monitoring features for integration with fire alarm interfaces. - Where is this module typically installed?
It is commonly mounted inside access control cabinets or directly onto compatible controller footprints.
Additional Information
- Designed to match the mounting footprints of common Australian access control systems.
- Self healing fuses reduce maintenance visits and spare parts requirements.
- Commonly specified in commercial access control installations where fire trip compliance is required.
Technical Drawing