FSH FES90M-P Electric Strike – Fully Monitored with 35kg Pre-Load – 4 Hour Fire Rated
Key Features
- Motorised electric strike with up to 35kg pre-load and side-load tolerance.
- Fully monitored strike providing door latch and lock status feedback.
- Field selectable fail safe or fail secure operation.
- Multi-voltage operation from 10V DC to 30V DC.
- Very high holding strength exceeding 1300kg.
- Low current consumption with reduced draw in sleep mode.
- Supplied with 10mm strike lip and includes 5mm lip extension.
- Fire rated up to 4 hours when installed in approved assemblies.
Fire Rated
- Successfully fire rated up to 4 hours on fire door assemblies.
- Tested in accordance with AS/NZS 1905 Part 1 and BS 476 Part 22.
Specifications
- Item Code: FES90MP
- Function: Field selectable fail safe or fail secure
- Operating Voltage: 10V DC to 30V DC
- Current Draw: 300mA at 12V DC (action mode); 15mA at 12V DC (sleep mode)
- Pre-Load Capability: Up to 35kg
- Holding Strength: Over 1300kg
- Monitoring: Door latch status and lock status
- Construction: Stainless steel
- Durability: Tested to 1.5 million cycles with full pre-load
- Fire Rating: Up to 4 hours
- Weather Resistance: Suitable for exposed installations
- Latch Compatibility: 18mm latch with 3mm door gap
What's In The Box
- FSH FES90M-P motorised electric strike
- 10mm strike lip (fitted)
- 5mm lip extension
- Tab mounting kit
- Self-adhesive installation template
Suitable Uses
- Commercial access control doors where door pre-load is unavoidable.
- High traffic doors requiring monitored locking.
- Installations where energy efficiency and durability are critical.
Dimensions
Download PDF Resources
| FSH FES90M-P Electric Strike Data Sheet |
Frequently Asked Questions
- What does 35kg pre-load capability mean?
It means the strike can unlock even when the door is pushing against it with up to 35 kilograms of force. - Is this strike suitable for fire doors?
Yes, when installed in an approved fire door assembly it is rated up to 4 hours. - What is a common installation mistake to avoid?
Not allowing for correct latch projection and door gap, which can prevent proper monitoring and unlocking.
Additional Information
- Motorised EcoStrike technology is commonly selected where traditional solenoid strikes struggle with door pressure.
- Sleep mode reduces power consumption in access control systems that remain locked for long periods.
- Extension lips are available to suit deeper frame profiles if required.
Technical Drawing