Dormakaba TS83 Door Closer EN3-6 with Hold Open Arm – Silver

Key features icon Key Features

  • Heavy duty surface mounted door closer with EN3-6 adjustable spring strength.
  • Standard arm with hold open function and on/off switch.
  • Non-handed design for left or right hand doors.
  • Separate valves for closing speed and latching speed.
  • Self regulating or valve adjustable backcheck.
  • Adjustable delayed action for controlled closing.
  • Suitable for doors up to 1400 mm wide.
  • Supplied with parallel arm bracket.

Specifications icon Specifications

  • Item Code: DOTS8301SIL
  • Closer Series: TS83
  • Spring Strength: EN3-6 (adjustable by screw)
  • Door Width: Up to 1400 mm (parallel arm mounting up to 950 mm)
  • Handing: Non-handed
  • Hold Open: Yes (arm with on/off switch)
  • Backcheck: Yes (self regulating or valve adjustable)
  • Delayed Action: Yes
  • Slide Arm: No
  • Parallel Arm Bracket: Included
  • Fire Rated: No (hold open arms are not approved for fire door assemblies)
  • Finish: Silver

Contents icon What's In The Box

  • TS83 door closer body
  • Standard hold open arm assembly
  • Parallel arm bracket
  • Fixings

Suitable uses icon Suitable Uses

  • Commercial and industrial internal doors.
  • High traffic doorways.
  • Doors up to 1400 mm wide requiring heavy duty closer performance.
  • Applications requiring adjustable power and hold open function.

Dimensions

Dimension Size
Body size 245 mm (L) × 46 mm (W) × 60 mm (H)
Weight 1.7 kg

FAQ icon Frequently Asked Questions

  • Is this closer suitable for fire doors?
    No. The hold open arm configuration is not approved for fire door assemblies.
  • Can the hold open function be disabled?
    Yes. The hold open arm includes an on/off switch for user control.
  • What is a common installation issue?
    Incorrect spring adjustment for the door size can lead to poor closing or latching performance.

Additional information icon Additional Information

  • The TS83 is widely used in commercial environments due to its higher power range and durability.
  • Often specified for larger or heavier doors where lighter closers are insufficient.
  • Hold open arms are convenient for traffic flow but must not be used on fire rated door assemblies.