CS Technologies Evolution IP Communication Module (Suits EVO2 and EVO4) - CS4612
The CS Technologies CS4612 Evolution IP Communication Module is an optional networking adapter designed to provide fast and reliable Ethernet communication between CS Evolution software and CSEVO2 and CSEVO4 access controllers.
It enables network-based controller management and monitoring and is commonly specified where controllers must communicate over local area networks rather than serial connections.
Key Features
- Provides Ethernet networking for CSEVO2 and CSEVO4 controllers.
- Designed as a direct functional replacement for the Lantronix Xport Direct+ module (CS4611).
- Uses Lantronix Xport Direct network communication technology.
- Built-in web server for browser-based configuration.
- Auto Dynamic Host Configuration Protocol enabled by default.
- 256-bit Advanced Encryption Standard encryption for secure communications.
- RJ45 Ethernet interface with link and activity indicators.
Specifications
- Item Code: CS4612
- Product Type: Communication module
- Suits: CSEVO2 and CSEVO4 controllers
- Network Interface: RJ45 Ethernet
- Encryption: 256-bit Advanced Encryption Standard
- Operating System: Embedded real time operating system
- Configuration: Built-in web interface and Lantronix DeviceInstaller utility
- Headers: Two 12-pin, 2 mm headers for controller connection
What's In The Box
- CS4612 Evolution IP communication module
Suitable Uses
- Networked access control installations using CSEVO2 controllers.
- Networked access control installations using CSEVO4 controllers.
- Sites requiring Ethernet-based communication to CS Evolution software.
Evolution IP Communication Module - Item Code Family
Software & Resources
Frequently Asked Questions
- Is this module required for all EVO installations?
No. It is only required where Ethernet network communication is needed between the controller and the CS Evolution software. - Can this replace an older CS4611 module?
Yes. It is a direct functional replacement for the CS4611 Lantronix Xport Direct+ module. - How is the module configured on the network?
Configuration can be performed through the built-in web interface or using the Lantronix DeviceInstaller utility.
Additional Information
- This module is commonly specified in Australian commercial access control systems where controllers are distributed across a network.
- When replacing legacy CS4611 modules, existing network settings should be reviewed before commissioning.
- Ensure network security policies allow the required ports and protocols for Evolution software communication.